Introduction
If you are experiencing issues with your Alde system not producing enough or any hot water, follow these steps to troubleshoot and resolve the problem.
1. Confirm Alde Settings
- Access the Alde Control Panel.
- Press Menu and check the shower symbol:
- Halfway mode = Normal hot water mode.
- Boost mode = Extra hot water for 30 minutes.
- Ensure hot water mode is turned on.
2. Check Glycol and Water Temperature
- Navigate to Settings > Service on the Alde panel.
- Scroll down to view Glycol Temp and Water Temp.
- Ideal water temperature should be at least 120-130°F before using hot water.
3. Verify Nautilus System Settings
- If using city water connection, set the Nautilus system to city water mode.
- If using onboard water tank, set it to dry camping mode.
- Ensure the bypass valve (if using a Nautilus P2.5) for the hot water tank is in the vertical position.
4. Adjusting the Mixing Valve
A. Adjusting the Old-Style Mixing Valve (Black Cap)
- If not enough hot water:
- Turn the knob toward the plus (+) symbol.
- If maxed out and still insufficient, remove the black cap:
- Use a flathead screwdriver to loosen the screw.
- Inside, adjust the black piece until it aligns with the outside ring.
- Do not go past this point to prevent system failure.
- Reattach the cap and tighten the screw securely.
B. Adjusting the New-Style Mixing Valve (Red Cap)
- Pop off the red cap.
- Use the cutout on the capto adjust the valve:
- Counterclockwise = More hot water.
- Clockwise = Less hot water.
- Ensure the hot water line (red) is connected to the “H” side and the cold water line (blue) is connected to the “C” side.
- If stripped, use a 5/16 socket wrench to adjust.
5. Locating the Mixing Valve in Different Models
TAB 400
- Located in the bed area.
- Remove two screws, lift the panel, and adjust the mixing valve.
TAB 320
- Located under the driver’s side bed area.
- Remove the cushion and open the panel to access the mixing valve.
Cirrus 820
- Located under the dining area seat.
- Remove the cushion, open the panel, and access the mixing valve.
6. Contact Technical Support if Needed
If you still experience issues after following these steps, reach out to:
- nuCamp Technical Support: tech@nucamprv.com
Thank you, and we hope this helps resolve your hot water issue!
Link to video: Adjusting the Alde Mixing Valve